Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Osteoarthr Cartil Open ; 5(4): 100416, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38107076

RESUMO

Objective: To develop an imaging mass cytometry method for identifying complex cell phenotypes, inter-cellular interactions, and population changes in the synovium and infrapatellar fat pad (IFP) of the mouse knee following a non-invasive compression injury. Design: Fifteen male C57BL/6 mice were fed a high-fat diet for 8 weeks prior to random assignment to sham, 0.88 â€‹mm, or 1.7 â€‹mm knee compression displacement at 24 weeks of age. 2-weeks after loading, limbs were prepared for histologic and imaging mass cytometry analysis, focusing on myeloid immune cell populations in the synovium and IFP. Results: 1.7 â€‹mm compression caused anterior cruciate ligament (ACL) rupture, development of post-traumatic osteoarthritis, and a 2- to 3-fold increase in cellularity of synovium and IFP tissues compared to sham or 0.88 â€‹mm compression. Imaging mass cytometry identified 11 myeloid cell subpopulations in synovium and 7 in IFP, of which approximately half were elevated 2 weeks after ACL injury in association with the vasculature. Notably, two monocyte/macrophage subpopulations and an MHC IIhi population were elevated 2-weeks post-injury in the synovium but not IFP. Vascular and immune cell interactions were particularly diverse in the synovium, incorporating 8 unique combinations of 5 myeloid cell populations, including a monocyte/macrophage population, an MHC IIhi population, and 3 different undefined F4/80+ myeloid populations. Conclusions: Developing an imaging mass cytometry method for the mouse enabled us to identify a diverse array of synovial and IFP vascular-associated myeloid cell subpopulations. These subpopulations were differentially elevated in synovial and IFP tissues 2-weeks post injury, providing new details on tissue-specific immune regulation.

2.
Cytometry A ; 103(12): 1010-1018, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37724720

RESUMO

Imaging mass cytometry (IMC) is a powerful spatial technology that utilizes cytometry time of flight to acquire multiplexed image datasets with up to 40 markers, via metal-tagged antibodies. Recent advances in IMC have led to the inclusion of RNAScope probes and multiple new analysis pipelines have led to faster analyses and better results. However, IMC still suffers from lower resolution (1 µm2 pixels) and relatively small regions of interest (ROIs) (<2 mm2 ) compared to other, light-based microscope technologies. Capturing higher-resolution images on serial sections causes great difficulty when attempting to align cells and structures across serial sections, especially when observing smaller cell types and structures. Therefore, we demonstrate the combination of H&E and multiplex immunofluorescence imaging, for much higher resolution of the structural and cellular compartments found throughout the entire tissue section, with the high-dimensionality of IMC for specific ROIs on a single slide. Additionally, we demonstrate a simple and effective open-source cell segmentation and IMC analysis pipeline with previously published and freely available software.


Assuntos
Anticorpos , Citometria por Imagem , Imunofluorescência , Citometria por Imagem/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...